RRI Banner

Surface adjustment of the IRAM 30 m radio telescope

dc.contributor.authorMorris, D.
dc.contributor.authorBremer, M.
dc.contributor.authorButin, G.
dc.contributor.authorCarter, M.
dc.contributor.authorGreve, A.
dc.contributor.authorLamb, J.W.
dc.contributor.authorLazareff, B.
dc.contributor.authorLopez-Perez, J.
dc.contributor.authorMattiocco, F.
dc.contributor.authorPenalver, J.
dc.contributor.authorThum, C.
dc.date.accessioned2009-05-18T06:39:01Z
dc.date.available2009-05-18T06:39:01Z
dc.date.issued2009-01-23
dc.descriptionRestricted Access.en
dc.description.abstractThe techniques used to set and stabilise the surface of the IRAM 30 m radio telescope to a final root mean square accuracy of about 50 µm are described. This involved both phase retrieval and phase coherent holography using a variety of radiation sources at several frequencies. A finite-element model was utilised in improving the temperature control system for the telescope structure. The factors influencing the ultimate surface accuracy are discussed.en
dc.identifier.citationIET Microwaves, Antennas & Propagation, 2009, Vol. 3(1), p99-108en
dc.identifier.issn1751-8725
dc.identifier.issn1751-8733 (Online)
dc.identifier.urihttp://hdl.handle.net/2289/3757
dc.language.isoenen
dc.publisherInstitution of Engineering and Technologyen
dc.relation.urihttp://dx.doi.org/10.1049/iet-map:20080044en
dc.rights2009 Institution of Engineering and Technologyen
dc.titleSurface adjustment of the IRAM 30 m radio telescopeen
dc.typeArticleen

Files