Surface adjustment of the IRAM 30 m radio telescope
| dc.contributor.author | Morris, D. | |
| dc.contributor.author | Bremer, M. | |
| dc.contributor.author | Butin, G. | |
| dc.contributor.author | Carter, M. | |
| dc.contributor.author | Greve, A. | |
| dc.contributor.author | Lamb, J.W. | |
| dc.contributor.author | Lazareff, B. | |
| dc.contributor.author | Lopez-Perez, J. | |
| dc.contributor.author | Mattiocco, F. | |
| dc.contributor.author | Penalver, J. | |
| dc.contributor.author | Thum, C. | |
| dc.date.accessioned | 2009-05-18T06:39:01Z | |
| dc.date.available | 2009-05-18T06:39:01Z | |
| dc.date.issued | 2009-01-23 | |
| dc.description | Restricted Access. | en |
| dc.description.abstract | The techniques used to set and stabilise the surface of the IRAM 30 m radio telescope to a final root mean square accuracy of about 50 µm are described. This involved both phase retrieval and phase coherent holography using a variety of radiation sources at several frequencies. A finite-element model was utilised in improving the temperature control system for the telescope structure. The factors influencing the ultimate surface accuracy are discussed. | en |
| dc.identifier.citation | IET Microwaves, Antennas & Propagation, 2009, Vol. 3(1), p99-108 | en |
| dc.identifier.issn | 1751-8725 | |
| dc.identifier.issn | 1751-8733 (Online) | |
| dc.identifier.uri | http://hdl.handle.net/2289/3757 | |
| dc.language.iso | en | en |
| dc.publisher | Institution of Engineering and Technology | en |
| dc.relation.uri | http://dx.doi.org/10.1049/iet-map:20080044 | en |
| dc.rights | 2009 Institution of Engineering and Technology | en |
| dc.title | Surface adjustment of the IRAM 30 m radio telescope | en |
| dc.type | Article | en |