Surface adjustment of the IRAM 30 m radio telescope
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Institution of Engineering and Technology
DOI
Abstract
The techniques used to set and stabilise the surface of the IRAM 30 m radio telescope to a final root mean square accuracy of about 50 µm are described. This involved both phase retrieval and phase coherent holography using a variety of radiation sources at several frequencies. A finite-element model was utilised in improving the temperature control system for the telescope structure. The factors influencing the ultimate surface accuracy are discussed.
Description
Restricted Access.
Keywords
Citation
IET Microwaves, Antennas & Propagation, 2009, Vol. 3(1), p99-108
Collections
Endorsement
Review
Supplemented By
Referenced By
Rights and licensing