Please use this identifier to cite or link to this item: http://hdl.handle.net/2289/6995
Title: Comparing Redundant and Sky-model-based Interferometric Calibration: A First Look with Phase II of the MWA
Authors: LI, W
Paul, Sourabh
Sethi, S.K.
Udaya Shankar, N.
Subrahmanyan, Ravi
+ 51 Co-authors
Keywords: dark ages
reionization
first stars – instrumentation
interferometers – methods
data analysis – techniques
interferometric
Issue Date: 20-Aug-2018
Publisher: IOP Sciences for The American Astronomical Society
Citation: Astrophysical Journal, 2018, Vol. 863, p170
Abstract: Interferometric arrays seeking to measure the 21 cm signal from the epoch of reionization (EOR) must contend with overwhelmingly bright emission from foreground sources. Accurate recovery of the 21 cm signal will require precise calibration of the array, and several new avenues for calibration have been pursued in recent years, including methods using redundancy in the antenna configuration. The newly upgraded Phase II of Murchison Widefield Array (MWA) is the first interferometer that has large numbers of redundant baselines while retaining good instantaneous UV coverage. This array therefore provides a unique opportunity to compare redundant calibration with sky-model-based algorithms. In this paper, we present the first results from comparing both calibration approaches with MWA Phase II observations. For redundant calibration, we use the package OMNICAL and produce sky-based calibration solutions with the analysis package Fast Holographic Deconvolution (FHD). There are three principal results: (1) We report the success of OMNICAL on observations of ORBComm satellites, showing substantial agreement between redundant visibility measurements after calibration. (2) We directly compare OMNICAL calibration solutions with those from FHD and demonstrate that these two different calibration schemes give extremely similar results. (3) We explore improved calibration by combining OMNICAL and FHD. We evaluate these combined methods using power spectrum techniques developed for EOR analysis and find evidence for marginal improvements mitigating artifacts in the power spectrum. These results are likely limited by the signal-to-noise ratio in the 6 hr of data used, but they suggest future directions for combining these two calibration schemes.
Description: Open Access
URI: http://hdl.handle.net/2289/6995
ISSN: 0004-637X
1538-4357-(Online)
Alternative Location: http://adsabs.harvard.edu/abs/2018ApJ...863..170L
https://arxiv.org/abs/1807.05312
https://doi.org/10.3847/1538-4357/aad3c3
Copyright: 2018, The American Astronomical Society
Appears in Collections:Research Papers (A&A)

Files in This Item:
File Description SizeFormat 
2018_ApJ_Vol.863_p170.pdfOpen Access1.68 MBAdobe PDFView/Open


Items in RRI Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.