RRI Banner

A simple technique for measurement of the voltage dependent capacitance of pixels in liquid crystal displays

dc.contributor.authorRuckmongathan, T.N.
dc.contributor.authorJuneja, Prabhjot
dc.contributor.authorShashidhara, A.R.
dc.date.accessioned2006-12-06T07:39:10Z
dc.date.available2006-12-06T07:39:10Z
dc.date.issued2006-10
dc.descriptionPaper presented at the Proceedings of the Asian Symposium on Information Display (ASID'06), Oct. 8-12, 2006.en
dc.description.abstractA technique for measuring the voltage dependent capacitance of pixels by using a low cost integrated circuit and some common laboratory equipments is proposed. The error in measurement ranges from 1 to 2% and this technique can be used for indirect measurement of various parameters of the liquid crystals.en
dc.format.extent200593 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.citationProceedings of the Asian Symposium on Information Display (ASID'06), Oct. 8-12, 2006, p23-26en
dc.identifier.urihttp://hdl.handle.net/2289/1561
dc.language.isoenen
dc.publisherSociety for Information Displayen
dc.relation.urihttp://www.rri.res.in/~ruck/Publications/asid06js.pdfen
dc.rightsThis paper is made available with permission of the Society for Information Display. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.en
dc.subjectCapacitance measurementen
dc.subjectCapacitance of liquid crystal cellen
dc.subjectRCA CD4047Ben
dc.titleA simple technique for measurement of the voltage dependent capacitance of pixels in liquid crystal displaysen
dc.typeArticleen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2006 ASID 06 p23.pdf
Size:
195.89 KB
Format:
Adobe Portable Document Format
Description:
6p.