RRI Banner

Design of standard loads for calibrating the receiver at the antenna port

dc.contributor.authorRaghunathan, A
dc.contributor.authorSandhya
dc.contributor.authorArasi, S
dc.date.accessioned2021-12-14T08:40:56Z
dc.date.available2021-12-14T08:40:56Z
dc.date.issued2019-05-13
dc.descriptionRestricted Accessen_US
dc.description.abstractGenerally receiver systems are calibrated for their gain and phase characteristics using standard loads such as Short, Open and 50 ohms. In all these modules, connecting ports have two terminals – centre conductor and the ground. So connecting them to receiver modules having similar port types do not create any problem. However, to connect them to antenna port which has only centre conductor, we normally face difficulties due to port mismatch. To solve this problem, a microstrip transmission line based standard loads are designed which can be used to calibrate at the antenna port. This report presents the methodology of designing loads for the antenna port.en_US
dc.identifier.citationRRI-EEG Internal Technical Reporten_US
dc.identifier.urihttp://hdl.handle.net/2289/7859
dc.language.isoenen_US
dc.rights2019 Raman Research Institute, Bengaluruen_US
dc.titleDesign of standard loads for calibrating the receiver at the antenna porten_US
dc.typeTechnical Reporten_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
std_load_for_calibrating_at_antenna_port_internal_report.pdf
Size:
488.33 KB
Format:
Adobe Portable Document Format
Description:
Open Access

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.76 KB
Format:
Item-specific license agreed upon to submission
Description: