RRI Banner

Development of focal plane detectors for the Nuclear Spectroscopic Telescope Array (NuSTAR) mission

dc.contributor.authorRana, Vikram
dc.contributor.authorCook III, Walter R
dc.contributor.authorHarrison, Fiona A
dc.contributor.authorMao, Peter H
dc.contributor.authorMiyasaka, Hiromasa
dc.date.accessioned2019-10-31T08:48:03Z
dc.date.available2019-10-31T08:48:03Z
dc.date.issued2009-09-02
dc.descriptionRestricted Accessen_US
dc.description.abstractThe Nuclear Spectroscopic Telescope Array (NuSTAR), scheduled for launch in 2011, is a NASA Small Explorer mission that will improve the current sensitivity for detection of faint astrophysical sources in the 6-80 keV band by two orders of magnitude. NuSTAR achieves high sensitivity by utilizing a hard X-ray focusing system. We have developed Cadmium Zinc Telluride (CdZnTe) pixel detectors optimized for good energy for the NuSTAR focal plane. Each of NuSTAR's two focal planes is comprised of hybrid detectors that consist of a CdZnTe pixel sensor with the anode contacts directly attached to corresponding readout circuits integrated on a custom low-noise VLSI chip. Each hybrid is 20.5 x 20.5 x 2.0 mm in size with the anode divided into 32 x 32 array of pixels at 0.6048 mm. In this paper we describe the hybrid sensor architecture, and present preliminary results from the characterization of detectors fabricated for the NuSTAR focal plane Engineering Test Unit (ETU). We achieve excellent electronic readout noise with an average of 250 eV FWHM, and energy resolution between 0.9 and 1.6 keV FWHM at 86.5 keV, depending on position in the sensor and improving at lower energies. In order to achieve the best spectral resolution we need to make pixeldependent corrections for events with charge split among multiple pixels, and in addition we make spectral corrections based on depth of the gamma-ray interaction.en_US
dc.identifier.citationProceedings of the SPIE ,2009, Vol.7435, p743503, UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XVI, edited by Oswald H. Siegmunden_US
dc.identifier.issn0277-786X
dc.identifier.urihttp://hdl.handle.net/2289/7340
dc.language.isoenen_US
dc.publisherSPIE - The International Society for Optics and Photonicsen_US
dc.relation.urihttp://adsabs.harvard.edu/abs/2009SPIE.7435E..03Ren_US
dc.relation.urihttps://doi.org/10.1117/12.825418en_US
dc.rights2000 SPIE-The International Society for Optical Engineeringen_US
dc.subjectHard X-ray astrophysicsen_US
dc.subjectpixilated CdZnTe detectorsen_US
dc.subjectelectronic noise and spectral performance,en_US
dc.subjectNuSTARen_US
dc.titleDevelopment of focal plane detectors for the Nuclear Spectroscopic Telescope Array (NuSTAR) missionen_US
dc.typeArticleen_US

Files