Revisiting wideband pulsar timing measurements
| dc.additional | Collection: RAS Journals | en_US |
| dc.contributor.author | Susobhanan, Abhimanyu | |
| dc.contributor.author | Paladi, Avinash Kumar | |
| dc.contributor.author | Desmecht, Réka | |
| dc.contributor.author | Amarnath | |
| dc.contributor.author | Bagchi, Manjari | |
| dc.contributor.author | Chakraborty, Manoneeta | |
| dc.contributor.author | Chowdhury, Shaswata | |
| dc.contributor.author | Das, Suruj Jyoti | |
| dc.contributor.author | Deb, Debabrata | |
| dc.contributor.author | Desai, Shantanu | |
| dc.contributor.author | Dwivedi, Churchil | |
| dc.contributor.author | Grover, Himanshu | |
| dc.contributor.author | Jose, Jibin | |
| dc.contributor.author | Joshi, Bhal Chandra | |
| dc.contributor.author | Kala, Shubham | |
| dc.contributor.author | Kareem, Fazal | |
| dc.contributor.author | Meena, Kuldeep | |
| dc.contributor.author | Mondal, Sushovan | |
| dc.contributor.author | Nobleson, K | |
| dc.contributor.author | Pandian, B Arul | |
| dc.contributor.author | Rai, Kaustubh | |
| dc.contributor.author | Shukla, Adya | |
| dc.contributor.author | Singh, Manpreet | |
| dc.contributor.author | Srivastava, Aman | |
| dc.contributor.author | Surnis, Mayuresh | |
| dc.contributor.author | Tahbildar, Hemanga | |
| dc.contributor.author | Takahashi, Keitaro | |
| dc.contributor.author | Tarafdar, Pratik | |
| dc.contributor.author | Vara, Kunjal | |
| dc.contributor.author | Vyasraj, Vaishnavi | |
| dc.contributor.author | Zuraiq, Zenia | |
| dc.date.accessioned | 2026-04-15T05:10:40Z | |
| dc.date.available | 2026-04-15T05:10:40Z | |
| dc.date.issued | 2026-03-09 | |
| dc.description | Open Access. Also available at arXiv.org (one of the alternative locations) | en_US |
| dc.description.abstract | In the wideband paradigm of pulsar timing, the time of arrival of a pulsar pulse is measured simultaneously with the corresponding dispersion measure from a frequency-resolved integrated pulse profile. We present a new method for performing wideband measurements that rigorously accounts for measurement noise. We demonstrate this method using observations of PSR J2124−3358 made as part of the Indian Pulsar Timing Array experiment using the upgraded Giant Metre-wave Radio Telescope, and show that our method produces more realistic measurement uncertainty estimates compared to the existing wideband measurement method. | en_US |
| dc.identifier.citation | Monthly Notices of the Royal Astronomical Society, 2026, Vol. 547 (4), AR No. stag444 | en_US |
| dc.identifier.issn | 1365-2966 | |
| dc.identifier.uri | http://hdl.handle.net/2289/8706 | |
| dc.language.iso | en | en_US |
| dc.publisher | Monthly Notices of the Royal Astronomical Society | en_US |
| dc.relation.uri | https://doi.org/10.48550/arXiv.2512.01288 | en_US |
| dc.relation.uri | https://doi.org/10.1093/mnras/stag444 | en_US |
| dc.rights | © The Author(s) 2026 | en_US |
| dc.subject | methods: data analysis | en_US |
| dc.subject | pulsars: general | en_US |
| dc.title | Revisiting wideband pulsar timing measurements | en_US |
| dc.type | Article | en_US |

