Please use this identifier to cite or link to this item:
http://hdl.handle.net/2289/4742| Title: | Current status of the X-ray polarimeter |
| Authors: | Rishin, P V Gopalakrishna, M R Paul, Biswajit Duraichelvan, R Ateequlla, C M Maitra, Chandreyee Rajagopala, G Nagaraja, H N Ezhilarasi, M S Sandhya, P Mamatha, T S |
| Issue Date: | 2011 |
| Citation: | RRI In-House Meet, 2011 |
| Abstract: | We describe the current status of a Thomson X-ray polarimeter developed for a small satellite mission. Currently, a laboratory model has been made and tested successfully and the design and fabrication of an engineering model is in progress. This involves, re-design of the currently developed lab model, taking into consideration the different standards required for space qualification. We describe the design aspects of the detector, front-end electronics and the processing electronics. |
| Description: | Open Access |
| URI: | http://hdl.handle.net/2289/4742 |
| Copyright: | 2011 Raman Research Institute |
| Appears in Collections: | Posters |