Please use this identifier to cite or link to this item:
                
    
    http://hdl.handle.net/2289/3757| Title: | Surface adjustment of the IRAM 30 m radio telescope | 
| Authors: | Morris, D. Bremer, M. Butin, G. Carter, M. Greve, A. Lamb, J.W. Lazareff, B. Lopez-Perez, J. Mattiocco, F. Penalver, J. Thum, C. | 
| Issue Date: | 23-Jan-2009 | 
| Publisher: | Institution of Engineering and Technology | 
| Citation: | IET Microwaves, Antennas & Propagation, 2009, Vol. 3(1), p99-108 | 
| Abstract: | The techniques used to set and stabilise the surface of the IRAM 30 m radio telescope to a final root mean square accuracy of about 50 µm are described. This involved both phase retrieval and phase coherent holography using a variety of radiation sources at several frequencies. A finite-element model was utilised in improving the temperature control system for the telescope structure. The factors influencing the ultimate surface accuracy are discussed. | 
| Description: | Restricted Access. | 
| URI: | http://hdl.handle.net/2289/3757 | 
| ISSN: | 1751-8725 1751-8733 (Online) | 
| Alternative Location: | http://dx.doi.org/10.1049/iet-map:20080044 | 
| Copyright: | 2009 Institution of Engineering and Technology | 
| Appears in Collections: | Research  Papers (A&A) | 
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 2009 IET_MAP V3 p99-108.pdf Restricted Access | 10p. | 509.24 kB | Adobe PDF | View/Open Request a copy | 
Items in RRI Digital Repository are protected by copyright, with all rights reserved, unless otherwise indicated.